Hair removal treatment using 1,064 nm long-pulsed Nd:YAG laser in auricular post reconstruction of microtia patient: two case reports
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.
Microtia is a congenital anomaly of the external and middle ear with various degrees of severity. The hair growth on the reconstructed auricle causes aesthetic problems. We describe two cases about the successful epilation of unwanted hair in postauricular reconstruction of microtia patients using 1,064 nm long-pulsed neodymium: ytrium-alumunium-garnet (LP Nd:YAG) laser in Fitzpatrick skin type IV patients, using 6x6 mm tip, 35 J/cm2 fluence, 10 ms pulse, and 1 Hz frequency with burnt of hair as an endpoint. On the follow up day 11 of case one and day 7 of case two, the hair reductions on treated auricles were 46% and 58%, respectively, with no adverse effects. Minimal 6 repeated sessions are recommended for optimal result. In these case reports, LP Nd:YAG laser treatment is considered effective for the unwanted hair growth on the reconstructed auricle in dark skin type patients with minimal risk of adverse effect.
PAGEPress has chosen to apply the Creative Commons Attribution NonCommercial 4.0 International License (CC BY-NC 4.0) to all manuscripts to be published.