Double decompression of presacral collection by heald anal stent and foley catheter combination


Published: November 8, 2011
Abstract Views: 1075
PDF: 406
HTML: 711
Publisher's note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.

Authors

The authors demonstrate the effective drainage of presacral sepsis following low anterior resection surgery using the novel approach of both the Heald anal stent and a Foley catheter combined. The Heald stent was placed trans-anally without the need for anaesthetic and an 18Fr Foley was placed through this. A presacral collection was drained through the stent, allowing the patient to be discharged after a week without the need to return to the operating theatre. The Heald stent may be used to successfully drain a presacral collection by double decompression of the rectum and the presacral space.

Guy F. Nash, Department of Surgery, Poole Hospital, Poole, Dorset

Surgery

Consultant Surgeon

Supporting Agencies

none

Godfrey, D. A., & Nash, G. F. (2011). Double decompression of presacral collection by heald anal stent and foley catheter combination. Surgical Techniques Development, 1(2), e28. https://doi.org/10.4081/std.2011.e28