All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.

Authors

We describe the novel use of a cannula in decompressing a large tension pneumoperitoneum secondary to perforated sigmoid diverticulum, in which the patient did not subsequently require an emergency laparotomy. Needle decompression was successfully used as part of a conservative regimen, thus avoiding potentially high-risk surgery.